BioSemi B.V.
Amsterdam, The NetherlandsFounded 1998
- EEG and neural monitoring
- Neuroscience research tools
BioSemi develops biopotential measurement equipment and active electrodes for scientific research, including systems for EEG, ECG, and EMG. Founded in 1998 by electronic engineers and a physicist, the company builds on academic research into multichannel measurement instrumentation.
- Founded
- 1998
- Employees
- 51–100
reccy insights
BioSemi was founded in 1998, with Robert Honsbeek identified as its founder. The company’s work centers on electrophysiology research and biopotential measurement equipment, including systems for EEG, ECG, and EMG. Its product range includes the ActiveTwo AD-Box, which supports acquisition across as many as 256 channels; the Analog Input Box, which adds up to 32 isolated analog input channels; and the Active3 System, designed for electrophysiological recording with optical-fiber connections and triggered hyperscanning capabilities. ActiView software supports data acquisition and visualization, including synchronized multichannel recording and trigger-timing analysis. The company’s technical approach includes active electrodes, DC-coupled acquisition, and a battery-powered front end with fiber-optic data transfer.
Written by reccy's AI from company sites, press and funding records · updated Oct 2026
What makes BioSemi B.V. distinct
- 01Pioneered one of the first commercially available systems with active electrodes.
- 02The ActiveThree system combines high signal quality, portability, low power consumption, and ease of use.
- 03Supports up to 142 EEG/EXG electrode and sensor channels with 24-bit, DC-coupled acquisition.
- 04Designed for measurements without skin preparation, with a battery-powered front end and fiber-optic data transfer.
- 05Developed from academic research in multichannel biopotential measurement.
Technology & products4
- ActiveTwo AD-Box
An amplifier module that measures signals from electrodes or sensors connected to a subject, supporting up to 256 channels for electrophysiological data acquisition.
- Analog Input Box (AIB)
An auxiliary device that adds up to 32 isolated analog input channels synchronized with the ActiveTwo AD-Box for integrated data acquisition.
- Active3 System
A research system for electrophysiological data acquisition featuring Mk3 electrode connectors, optical-fiber connections, and triggered hyperscanning capabilities.
+ 1 more: ActiView Software
Similar companies
About BioSemi B.V.
- Products
- ActiveTwo AD-Box, Analog Input Box (AIB), Active3 System, ActiView Software
- Leadership
- Robert Honsbeek, Founder
- Focus areas
- EEG, ECG, EMG, neuroscience research, biomedical instrumentation, active electrodes, biopotential measurement, research equipment
- Headquarters
- Amsterdam, The Netherlands
- Founded
- 1998
- Employees
- 51–100